Features:

sine wava inverter-chager
power rate 1500w-8000w In a units
parallel and 3 phase configuration up to 9 units
Outstanding efficiency and overload capabilities
Smart-Boost Function for assistance to the source
Inverter/charger with 50A transfer system
From 2 to 8kW for 12,24 or 48V DC systems
Up to 3 units in parallel
Configurable in 3 phase and 3 phase and parallel
Up to 24kW per phase -72kW three phase

Share
More Information
Features:
  Parallel and 3 phase configuration up to 9 units.
Outstanding efficiency and overload capabilities.
Smart‐Boost Function for assistance to the source.
Automatic reduction of peak loads.
Automatic allocation of the available power (power sharing).
Standby level adjustable from a very low load threshold.
Multi‐stage, fully programmable battery charger with PFC.
Ultra fast high power transfer relay.
Control by digital signal processor (DSP).
2 fully independently programmable auxiliary contacts.
Real time clock for event record and auxiliary relay programming.

Xtender range

Battery

Voltage

AC

Voltage

Output power

P30/Pnom

Power S Charge

current mart

Boost

Charge

current

Transfer

current

XTM 150012 (01)

12 Vdc

230 Vac

1500 / 1500 VA

1500 VA

0 – 70A

50 A

XTM 200012 (01)

12 Vdc

230 Vac

2000 / 2000 VA

2000 VA

0 – 55A

50A

XTM 240024 (01)

24 Vdc

230 Vac

2400 / 2000 VA

2400 VA

0 – 55A

50A

XTM 260048 (01)

48 Vdc

230 Vac

2600 / 2000 VA

2600 V

0 – 30A

50A

XTH 300012 (01)

12 Vdc

230 Vac

3000 / 2500 VA

3000 VA

0 – 160

50A

XTM 350024 (01)

24 Vdc

230 Vac

3500 / 3000 VA

3500 VA

0 – 90A

50A

XTM 400048 (01)

48 Vdc

230 Vac

4000 / 3500 VA

4000 VA

0 – 50A

50A

XTH 500024 (01)

24 Vdc

230 Vac

5000 / 4500 VA

5000 VA

0 – 1400A

50A

XTH 600048 (01)

48 Vdc

230 Vac

6000 / 5000 VA

6000 VA

0 – 100A

50A

XTH 800048

48 Vdc

230 Vac

8000 / 7000 VA

8000 VA

0 – 1200A

50A

 

Features and performance

· Inverter/charger with 50A transfer system
· From 2 to 8kW for 12,24 or 48V DC systems
· Up to 3 units in parallel
· Configurable in 3 phase and 3 phase and parallel
· Up to 24kW per phase -72kW three phase
· More than 100 accessible parameters
· Generator or grid power assistance “ Smart boost “
· Remote module for display and programming
· Event log on SD card
· Setup saving and restore from SD card
· Data acquisition on SD card ( end 2009)

RS232 for data acquisition and programming

Remote control and programming center RCC-02 or RCC-03

Display of all electrrical measured value of the Xtender network ( XTS.XTM.BSP)

Programming parameters of all connected devices ( including his own parameters)

Data and event log of connected devices on SD card

Configuration saving and downloading to and from SD card

Full firmware upgrade with the SD card

Extrea language download from SD card ( four embedded)

Isolates RD232 communication ( optinal)

Remote control module RCM-10 only for CTM with 3m Cable ( possible up to 5m)

DIN rail remote module for main on/off and function input management

Battery tempreture sensor BTS-01 with 3m Cable

This sensor enables to accurately adapt the charge thresholds to the battery tempreture .